Cathodic Protection

envirologics icon protect    Protect

Sacrificial anodes protect the exterior of the pipe by arresting future corrosion.  Anodes are strategically located to target vulnerable corrosion zones, extending the pipe's service life for decades.

Cathodic Protection Schematic

Cathodic protection uses zinc or magnesium anodes to protect pipe exterior as per AWWA M27 manual. Anodes are accurately located above the pipe using hydro excavation and results from the RFEC and video evaluation.  The anode lead (wire) is welded to the exterior of the pipe, the anode is placed in the ground and then covered over.  Locations of each anode is saved for future reference.
 
Protection Vac truck
  Protection anode  
 
The anodes can protect the pipe exterior from corrosion for up to 20 years and can be simply replaced once depleted.

Detective Assessment Probe

envirologics icon evaluate  Evaluate

Introduction to Remote Field Eddy Current (RFEC) Probe Technology

In its simplest form, an RFEC probe consists of two coils in a send-receive configuration. Figure 1 below shows a diagram of a simple RFEC probe in a deteriorated pipe. The exciter coil transmits an electromagnetic field and the detector coil receives a phase shifted, varying strength signal based on pipe wall thickness variations.

Probe pic 1a

Above, Basic Setup of RFEC probe in pipe.

The electromagnetic field is created by passing a low frequency current through the exciter coil. The field signal then travels from the exciter through the pipe wall, along the outside of the pipe and back through the wall to the detector coil. The signal phase shift and strength variations are analyzed by the probe software to provide anomaly details including pipe wall thickness change. The detector coil is set at a specific distance from the exciter coil (approximately three pipe diameters) and is “remote” enough that the exciter coil does not interfere with the recorded data.

Envirologics Detective Evaluation Description

Envirologics has incorporated the RFEC technology into the new Detective™ probe. After the pipe is cleaned, the Detective probe is pulled via the multi-conductor cable through the pipe using a winch system. A video camera is concurrently pulled through the pipe recording a visual inspection of the pipe interior as seen in figure below. 

Probe pic 2Above, Envirologics Detective evaluation schematic

probe pic 3a

                                        Above, Envirologics Detective RFEC Pipe Assessment Probe

Just like conventional RFEC technology the Detective works by detecting changes in the electromagnetic (EM) field generated by the probe. The EM field interacts with the metal in the encompassing pipe and becomes stronger in areas of metal loss. On the Detective device, the EM field interactions are captured by on-board detector coils and the data is sent “live-streaming” through the multi-conductor cable to the Eddy Current Main Frame processing unit.  The data is processed then viewed “live” via the laptop software.  Assessment data is stored on the computer for subsequent viewing and analysis.

Assessment and Video Data

The Detective software provides a simple, colour coded wall loss defects graph on a laptop screen to provide a quick audit of the pipe’s health. The areas of concern are highlighted in red based on defect severity. The threshold can also be changed within the software post scan in order to improve assessment capability.

The concurrently recorded video inspection is used to aid in distinguishing defects (DFT) from pipe joint (JT) and service connection (SC) locations, which are also shown in red on the RFEC scan graph

The simple interface data shown below allows the client to make quick decisions as to next steps in the rehabilitation process such as pipe repair (i.e. internal clamps), class 1 coating, class IV liner application, cathodic protection installations, or dig and replace of the pipe segment.

probe pic 4a

Above, Simplified Detective assessment scan data, SC = Service Connection, JT = Pipe Joint and DFT = corrosion defect.

The pictures below show a defect in cast iron pipe as viewed concurrently by both the video camera and the RFEC probe. These simultaneous evaluation methods have the added benefit of helping to determine levels of internal vs. external corrosion.

probe pic 5 and 6

Above,  Video inspection of cleaned pipe showing corrosion defect.  Right, Probe assessment scan showing same corrosion defect

Below shows an example of assessment data as viewed on the laptop screen with a 50% through wall (TW) color threshold setting at which the data points turn red.

 probe pic 7

Above, Assessment data as viewed on computer screen, 59% trhough wall (TW) threshold

The figure below is an example of assessment data that will be provided to the customer, indicated locations of joints and service connections.

probe pic 8

Above, RFEC Scan data provided in PDF format

Included with the assessment data will be a video inspection log. The log is used to locate such features as service connections, joints, pipe conditions such as leaks that were discovered during the CCTV inspection, etc. The video inspection and RFEC assessment data will be correlated by distance of features starting with 0m = start of pipe scan.

For an overview document that includes the information presented above along with specification, please click here.

Keep checking back to discover the latest developements with our Detective RFEC probe.